Air-cooled -50~250 degree cooling and heating machine dynamic temperature control machine SUNDI-5A10W

Air-cooled -50~250 degree cooling and heating machine dynamic temperature control machine SUNDI-5A10W

Price:
US 1-1,000,000 / Set
Min.Order Quantity:
1 Set/Sets
Supply Ability:
200 Set/Sets per Month
Port:
Shanghai
Place of Origin:
Jiangsu, China (Mainland)
Payment Terms:
T/T
Brand:
LNEYA
Products Model:
SUNDI-5A10W
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: LNEYA

    Model Number: SUNDI-5A10W

    Place of Origin: Jiangsu, China (Mainland)

Packaging & Delivery

  • Packaging Details: Standard wooden package
  • Delivery Detail: Within 20-25 working days

Specifications

Dynamic temperature control machine  

-50~250 degree      SUNDI-5A10

 

Product Description

Typical Applications

Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers

Advantages & Functions

Wide working temperatures

Previously unachievable performance

Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,the fastest heating and cooling rates.
High cooling power

Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact

7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature

Use magnetic drive pump,solve the circulation pump leakage

 

Structure design

 

 

The repeatability of temperature control result

 

Each cycle curve slope is consistent and greatly improve the consistency of the production thermostatically controlled environment. There is no overshoot occurred for reaction material and with fast and stable in the whole process.

Display funcation

The Refrigeration system's multi – image displays various information

1. Displays all the kind of process control temperatures.

2. Shows the liquid level of the heat conducting medium in the expansion vessel.

3. Shows indication for refrigeration system working.

4. Shows indication for heater working.

5. Shows indication for circulation pump working.

6. Displays the temperature control (materials temperature control pattern, heat conducting medium temperature control ).

7. The temperature upper limit, lower limit control can be set.

8. The temperature difference between jacket & reactor material can be set.

9. Shows the alarm to add the liquid when it is empty.

10. The refrigeration compressor can be set to operate manually or automatically.

Process control

Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings.

System with feedforward with PV, the master PID loop operation results of the PV output and feedforward signals as the composite of the settings from the control loop, through such control of the temperature gradient to ensure the accuracy of temperature control system.

 

Circulation Pump

High temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time the system has the advantages of low noise and big traffic flow.

 

 

Security

Many additional features to ensure the safe operation of the system. For the operation to run not normally appear in the alarm in time and displayed on the touch screen.

Phase sequence, leakage protection, refrigeration system high and low voltage protection, overload the pump, compressor overload, high and low level, two independent over-temperature protection, water protection, protection of the circulation line shut.

Connecting Pipe

 

 

LNEYA Dynamic Temperature Control systems in practice

In comparison to other thermal control systems, Dynamic Temperature Control systems differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process chain, greater safety for expensive glass reactors and the contained substances, together with simple and easy operation.

 

 

 

Heat Conduction Medium

It is important to choose the suitable heat conduction medium, to make sure that system works stably. To choose the suitable medium according to the working temperature of the system is essential.

The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L. when ordering the heat conduction medium, the heat conduction medium for constant temperature control system, channel, and external circulation equipments.

   

 Technical Parameters:

 

 
  • Email to this supplier
  • To :
    Jack Yan  |  wuxi guanya refrigeration technology co.,ltd
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - wuxi guanya refrigeration technology co.,ltd Bussiness Type:  Manufacturer
Scale:  51 - 100 People
Country/Region:  China (Mainland)/Asia
Established:  2012
You May Like:
cooling and heating oil chiller with cooling and heating capacity

cooling and heating water chiller system or industrial chiller

Cooling and heating 60KW 250L/min 2.5bar chiller system

50~ 250 degree good quality high temperature thermostat

Cooling and heating 25KW dynamic temperature control system chiller freezer